Continuous microwave-assisted isoflavone extraction system: Design and performance evaluation
Document Type
Article
Publication Date
1-1-2010
Abstract
The purpose of this research was to design, test, and optimize a continuous microwave extraction method using temperature and residence time during and after microwave exposure as optimizing parameters for extraction of major isoflavones (genistin, genistein, daidzin, and daidzein) from soy flour. The extraction yield of four isoflavones at different heating temperatures (55 and 73 °C) and extraction times (0, 4, 8, 12, and 16 min) were investigated and compared with yields provided by a conventional solvent extraction method. The microwave prototype consisted of multiple, commercially available, batch-type, house-hold microwave units placed on top of each other in series to impart a continuous operation. The optimum parameters for microwave-assisted extraction of isoflavones were 73 °C for 8 min using a 3:1 ethanolto soy flour ratio. At these parameters, the total yield of isoflavones extracted doubled, while the amount of oil extracted was 12%. Continuous microwave-assisted solvent extraction is a viable method for extraction of soybean isoflavones at relatively short residence times and high throughput. © 2009.
Publication Source (Journal or Book title)
Bioresource Technology
First Page
2466
Last Page
2471
Recommended Citation
Terigar, B., Balasubramanian, S., Boldor, D., Xu, Z., Lima, M., & Sabliov, C. (2010). Continuous microwave-assisted isoflavone extraction system: Design and performance evaluation. Bioresource Technology, 101 (7), 2466-2471. https://doi.org/10.1016/j.biortech.2009.11.039