We report the results from a year long study aimed at radiation resistance and optical performance of scintillator tile with green wave shifter fiber readout. A careful investigation of several rad-hard plastic scintillators from Bicron and Kuraray, studies indicate that for a specific rad-hard Bicron scintillator, it is possible to build a tile/fiber EM calorimeter that can operate in the design luminosity of SSC. This calorimeter with excellent optical response would only have a light loss of about 5% after being exposed to 1 Mrad. © 1993.
Publication Source (Journal or Book title)
Radiation Physics and Chemistry
First Page
243
Last Page
252
Recommended Citation
Fazely, A., Gunasingha, R., Imlay, R., Khosravi, E., Lim, J., Lyndon, C., McMills, G., McNeil, R., Metcalf, W., Courtney, J., Tashakkori, R., & Vegara, B. (1993). Radiation damage studies for the SDC electromagnetic calorimeter. Radiation Physics and Chemistry, 41 (1-2), 243-252. https://doi.org/10.1016/0969-806X(93)90062-Y