Abstract
Control of sperm concentration is required to ensure consistent and reproducible results for cryopreservation and in vitro fertilization protocols. Determination of sperm concentration is traditionally performed with a counting chamber (e.g., hemocytometer), or more recently with a spectrophotometer. For small-sized biomedical model fishes, the availability of sperm sample is limited to microliters, so it is desirable to develop fast and accurate approaches for concentration determination that also minimize sample use. In this study, a new approach was developed for sperm concentration determination using a flow cytometer (Accuri C6, BD Biosciences, San Jose, CA) with simultaneous measurement of sperm membrane integrity after fluorescent staining with SYBR®-14 and propidium iodide (PI) in sperm from Zebrafish Danio rerio. The goal was to develop a protocol for simultaneous determination of sperm quality and quantity by flow cytometry. The objectives were to (1) determine the effects of sample volume (250 and 500 μl) and analysis volume (10 and 50 μl) on the accuracy of particle counting using standard volumetric validation beads; (2) identify the effective range of sperm concentrations that flow cytometry can measure; (3) test the precision and reproducibility of the sperm concentration measurements; and (4) verify the flow cytometry approach by comparison with measurement with a hemocytometer and a microspectrophotometer. Sample volumes of 250 and 500 μl and analysis volumes of 10 and 50 μl did not affect bead count with the factory-set flow rates of "medium" or "fast," and the precision and accuracy was retained across a concentration range of 1 × 103-1 × 107 cells/ml. The approach developed in this study was comparable to traditional methodologies such as hemocytometer or microspectrophotometer. This study provides an efficient, accurate, and rapid method for determination of sperm concentration using flow cytometry while providing simultaneous assessment of sperm membrane integrity. Such approaches can reduce the time needed for quantity assessment and maximize the use of valuable sperm samples.
Publication Source (Journal or Book title)
Cytometry Part A
First Page
350
Last Page
356
Recommended Citation
Yang, H., Daly, J., & Tiersch, T. (2016). Determination of sperm concentration using flow cytometry with simultaneous analysis of sperm plasma membrane integrity in zebrafish Danio rerio. Cytometry Part A, 89 (4), 350-356. https://doi.org/10.1002/cyto.a.22796