Detailed mass transfer distribution in rotating, two-pass ribbed coolant channels with vortex generators
Document Type
Conference Proceeding
Publication Date
1-1-1999
Abstract
Local and global effects of cylindrical vortex generators on the mass transfer distributions over the four active walls of a square, rib-roughened rotating duct with a sharp 180 0 bend are investigated. Cylindrical vortex generators (rods) are placed above, and parallel to, every other rib on the leading and trailing walls of the duct so that their wake can interact with the shear layer and recirculation region formed behind the ribs, as well as the rotation-generated secondary flows. Local increases in nearwall turbulence intensity resulting from these interactions give rise to local enhancement of mass (heat) transfer. Measurements are presented for duct Reynolds numbers (Re) in the range 5000 - 30,000, and for rotation numbers in the range 0 to 0.3. The rib height-to-hydraulic diameter ratio (e/Dh) is fixed at 0.1, while the rib pitch-to-rib height ratio (P/e) is 10.5. The vortex generator rods have a diameter-to-rib height ratio (d/e) of 0.78, and the distance separating them from the ribs relative to the rib height (s/e) is 0.55. Mass transfer measurements of naphthalene sublimation have been carried out using an automated acquisition system and are correlated with heat transfer using the heat/mass transfer analogy. The results indicate that the vortex generators tend to enhance overall mass transfer in the duct, compared to the case where only ribs are present, both before and after the bend at high Reynolds and Rotation numbers. Local enhancements of up to 30% are observed on all four walls of the duct. At low Reynolds numbers (e.g. 5,000) the insertion of the rods often leads to degradation. At high Reynolds numbers (e.g. 30,000) the enhancement due to the rods occurs on the surfaces stabilized by rotation (trailing edge on the inlet pass and leading edge on the outlet pass) and the side walls. The enhancement is more pronounced as the Rotation number is increased. The detailed measurements in a ribbed duct with vortex-generator rods clearly show localized regions of enhanced mass (heat) transfer at Reynolds and Rotation numbers within the envelope of practical interest for gas-turbine blade cooling application.
Publication Source (Journal or Book title)
Proceedings of the ASME Turbo Expo
Recommended Citation
Eliades, V., Nikitopoulos, D., & Acharya, S. (1999). Detailed mass transfer distribution in rotating, two-pass ribbed coolant channels with vortex generators. Proceedings of the ASME Turbo Expo, 3 https://doi.org/10.1115/99-GT-424